WALL ISOLATION TYPE WC SERIES
WALL ISOLATION
Axial Load Capacity: 0.22kN
Shear Load Capacity: 0.78kN
APPLICATION
The WC series is used for resiliently connecting furring channels to masonry walls. Both variations come complete with fixings screws and channel clips. Resiliently mounting the furring channel helps reduce noise and vibration transmission through a wall cavity. Typically used on lift shaft and plant room walls.
FEATURES
• Resilient rubber isolating element
• Comes complete with furring channel clip
• Masonry fixings included on all variants
• Adjustable furring channel position on WFC Variant
• Easy installation
PERFORMANCE CHARACTERISTICS
Type WC
Working load
Tension: 220N
Shear: 780N
Type WFC
Working load
Tension: 220N
Shear: 780N